H3





1、 H3 load cells are available in the capacities 25kg to 30t and 100lb to 20klb.
2、 Alloy steel,sealed by adhesive inside,oil-proof,waterproof and anti-corrosion,suitable for all kinds of environments.
3、 S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices.
4、 Safe and anti-explosive product, can be used in atrocious environment and hazardous areas.
 
 
Specifications:
Capacity L H W1 W H1
25~50㎏  76.2 (3.0)  50.8 (2.0)  12.7 (0.5)  16.1 (0.63)  M8 15.7 (0.62) 
0.1~1.5t  76.2 (3.0)  50.8 (2.0)  19.0 (0.75)  22.4 (0.88)  M10×1.5  15.3 (0.60)
0.2~0.75t  76.2 (3.0)  50.8 (2.0)  19.0 (0.75)  22.4 (0.88) M12×1.75  13.6 (0.54)
1~1.5t  76.2 (3.0)  50.8 (2.0)  25.4 (1.0)  28.8 (1.13)  M12×1.75  12.1 (0.48)
2~5t  101.6 (4.0)  76.2 (3.0)  25.4 (1.0)  28.8 (1.13)  M20×1.5  20 (0.79) 
7.5~10t  175 (6.89)  125 (4.92)  50 (1.97)  M33×3  40.2 (1.58)
15~20t  200 (7.89)  160 (6.3)  60 (2.36)  M42×3  51 (2.01) 
30t  230 (9.06)  190 (7.48)  80 (3.15)  M42×3  57.5 (2.26) 
100~300lb  63.5 (2.5)  50.8 (2.0)  12.7 (0.5)  15.9 (0.63)  1/4—28UNF  10.1(0.4)
500lb  63.5 (2.5)  50.8 (2.0)  19.05 (0.75)  22.25 (0.88)  1/2—20UNF 
0.75~1.5klb  63.5 (2.5)  50.8 (2.0)  19.05 (0.75)  22.25 (0.88)  1/2—20UNF 
2~2.5klb  63.5 (2.5)  50.8 (2.0)  25.4 (1.0)  28.6 (1.13)  1/2—20UNF 
3klb  101.6 (4.0)  76.2 (3.0)  25.4 (1.0)  28.6 (1.13)  1/2—20UNF  15.24 (0.6) 
5~10klb  101.6 (4.0)  76.2 (3.0)  25.4 (1.0)  28.6 (1.13)  3/4—16UNF  15.24 (0.6)
15klb  139.7 (5.5)  101.6 (4.0)  31.75 (1.25)  34.95 (1.38)  1—14UNS  31 (1.22) 
20klb  177.8 (7.0)  127 (5.0)  50.8 (2.0)  54 (2.13)  5/4—12UNF  39.9 (1.57) 
 
 
 
 
Capacity 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 
lb  100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K 
Accuracy    C2  C3  C4  A5S  A5M  B10S  B10M 
Approval     OIML
R60 C3 
OIML 
R60 C4 
       
Maximum
number of
verification 
intervals
n max  2000  3000  4000  5000  5000  10000  10000 
Minimum 
load cell
verification 
interval 
v min  Emax
/5000 
Emax
/10000 
Emax
/14000 
Emax
/15000 
Emax
/15000 
Emax
/10000 
Emax
/10000 
Combined
error
%FS ≤±0.030  ≤±0.020  ≤±0.018  ≤±0.018  ≤±0.026  ≤±0.035  ≤±0.050 
Creep  %FS
/30min
≤±0.024  ≤±0.016  ≤±0.012  ≤±0.012  ≤±0.017  ≤±0.030  ≤±0.040 
Temperature
effect 
on sensitivity
%FS/10℃ ≤±0.017  ≤±0.011  ≤±0.009  ≤±0.009  ≤±0.013  ≤±0.030  ≤±0.040 
Temperature
effect 
on zero 
%FS/10℃ ≤±0.023  ≤±0.015  ≤±0.010  ≤±0.010  ≤±0.014  ≤±0.030  ≤±0.020 
Output
sensitivity 
mv/v 2.0±0.004(Metric) 3.0±0.008(Imperial) 
Input 
resistance 
Ω 350±3.5 
Output 
resistance 
Ω 351±2.0
Insulation 
resistance 
≥ 5000(50VDC) 
Zero balance  %FS 1.5(Metric) 1.0(Imperial) 
Temperature,
compensated
-10~+40 
Temperature,
operating
-35~+65 
Excitation,
Recommended
V 5~12(DC) 
Excitation,
Max
V 18(DC) 
Safe 