CONTACT US
sales@gromyscale.cn
|
H3

|
1、 H3 load cells are available in the capacities 25kg to 30t and 100lb to 20klb.
2、 Alloy steel,sealed by adhesive inside,oil-proof,waterproof and anti-corrosion,suitable for all kinds of environments.
3、 S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices.
4、 Safe and anti-explosive product, can be used in atrocious environment and hazardous areas.
Specifications:
|
Capacity |
L |
H |
W1 |
W |
M |
H1 |
|
25~50㎏ |
76.2 (3.0) |
50.8 (2.0) |
12.7 (0.5) |
16.1 (0.63) |
M8 |
15.7 (0.62) |
|
0.1~1.5t |
76.2 (3.0) |
50.8 (2.0) |
19.0 (0.75) |
22.4 (0.88) |
M10×1.5 |
15.3 (0.60) |
|
0.2~0.75t |
76.2 (3.0) |
50.8 (2.0) |
19.0 (0.75) |
22.4 (0.88) |
M12×1.75 |
13.6 (0.54) |
|
1~1.5t |
76.2 (3.0) |
50.8 (2.0) |
25.4 (1.0) |
28.8 (1.13) |
M12×1.75 |
12.1 (0.48) |
|
2~5t |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.8 (1.13) |
M20×1.5 |
20 (0.79) |
|
7.5~10t |
175 (6.89) |
125 (4.92) |
50 (1.97) |
/ |
M33×3 |
40.2 (1.58) |
|
15~20t |
200 (7.89) |
160 (6.3) |
60 (2.36) |
/ |
M42×3 |
51 (2.01) |
|
30t |
230 (9.06) |
190 (7.48) |
80 (3.15) |
/ |
M42×3 |
57.5 (2.26) |
|
100~300lb |
63.5 (2.5) |
50.8 (2.0) |
12.7 (0.5) |
15.9 (0.63) |
1/4—28UNF |
10.1(0.4) |
|
500lb |
63.5 (2.5) |
50.8 (2.0) |
19.05 (0.75) |
22.25 (0.88) |
1/2—20UNF |
|
0.75~1.5klb |
63.5 (2.5) |
50.8 (2.0) |
19.05 (0.75) |
22.25 (0.88) |
1/2—20UNF |
|
2~2.5klb |
63.5 (2.5) |
50.8 (2.0) |
25.4 (1.0) |
28.6 (1.13) |
1/2—20UNF |
|
3klb |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.6 (1.13) |
1/2—20UNF |
15.24 (0.6) |
|
5~10klb |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.6 (1.13) |
3/4—16UNF |
15.24 (0.6) |
|
15klb |
139.7 (5.5) |
101.6 (4.0) |
31.75 (1.25) |
34.95 (1.38) |
1—14UNS |
31 (1.22) |
|
20klb |
177.8 (7.0) |
127 (5.0) |
50.8 (2.0) |
54 (2.13) |
5/4—12UNF |
39.9 (1.57) |
|
Capacity |
t |
0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 |
|
lb |
100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K |
|
Accuracy |
|
C2 |
C3 |
C4 |
A5S |
A5M |
B10S |
B10M |
|
Approval |
|
|
OIML
R60 C3 |
OIML
R60 C4 |
|
|
|
|
Maximum
number of
verification
intervals |
n max |
2000 |
3000 |
4000 |
5000 |
5000 |
10000 |
10000 |
Minimum
load cell
verification
interval |
v min |
Emax
/5000 |
Emax
/10000 |
Emax
/14000 |
Emax
/15000 |
Emax
/15000 |
Emax
/10000 |
Emax
/10000 |
Combined
error |
%FS |
≤±0.030 |
≤±0.020 |
≤±0.018 |
≤±0.018 |
≤±0.026 |
≤±0.035 |
≤±0.050 |
|
Creep |
%FS
/30min |
≤±0.024 |
≤±0.016 |
≤±0.012 |
≤±0.012 |
≤±0.017 |
≤±0.030 |
≤±0.040 |
Temperature
effect
on sensitivity |
%FS/10℃ |
≤±0.017 |
≤±0.011 |
≤±0.009 |
≤±0.009 |
≤±0.013 |
≤±0.030 |
≤±0.040 |
Temperature
effect
on zero |
%FS/10℃ |
≤±0.023 |
≤±0.015 |
≤±0.010 |
≤±0.010 |
≤±0.014 |
≤±0.030 |
≤±0.020 |
Output
sensitivity |
mv/v |
2.0±0.004(Metric) 3.0±0.008(Imperial) |
Input
resistance |
Ω |
350±3.5 |
Output
resistance |
Ω |
351±2.0 |
Insulation
resistance |
MΩ |
≥ 5000(50VDC) |
|
Zero balance |
%FS |
1.5(Metric) 1.0(Imperial) |
Temperature,
compensated |
℃ |
-10~+40 |
Temperature,
operating |
℃ |
-35~+65 |
Excitation,
Recommended |
V |
5~12(DC) |
Excitation,
Max |
V |
18(DC) |
Safe
overload |
%FS |
150 |
Ultimate overload |
%FS |
300 |
|
|
|